Novec 1230 Fk5112 Fire Suppression System for Battery Room Energy Storage UPS Protection FM200 Fire System Clean Agent Hfc227ea Fire Fighting System

Still deciding? Get samples of $ !
Order Sample

Product Description

Basic Information
Model NO.
FFS
Object
Class A/B/C/D/E Fire
Certification
CCC, ISO9001
System Type
Automatic Fire Extinguisher
Retirement Life
8 Years
Agent Type
FK-5112 Novec 1230 / FM200
Filling Pressure
2.5MPa / 4.2MPa / 5.6MPa
HS Code
84241000
Product Description
Fire Suppression System 1
Fire Suppression System 2

FK-5112 Novec 1230 Clean Agent Total Flooding Fire System

FK-5-1-12 refers to an advanced automatic fire extinguishing equipment control system. Designed in cabinet and pipe network configurations, it can be customized as single-bottle or multi-bottle groups for various applications.

When set to "auto" mode, the system monitors the protected area using temperature and smoke detectors. Upon fire detection, it initiates a logic analysis, triggers sound and light alarms, closes linked devices, and releases the extinguishing agent after a brief delay to suppress the fire rapidly.

System Operation
Component Detail 1
Component Detail 2
Professional Design Solutions

We provide one-stop fire suppression solutions based on NFPA standards. Our engineers provide piping layout, cylinder capacity calculations, and CAD drawings tailored to your project requirements.

Design Drawing 1
Design Drawing 2
System Advantages
✔️ Easy to Operate & Maintain
🛡️ CCC Authenticated Quality
🔔 Real-time Detection Alarm
Fully Automatic Response
🔌 Non-Conductive (Safe for Electronics)
🌿 Environmentally Friendly (No Residue)
🧪 Non-Toxic & Safe for Humans
🚀 Rapid Fire Suppression
Product Specifications
Specification Technical Parameter
Filling Pressure 4.2Mpa 5.6Mpa
Protective Scale (Single Zone) Area: max 800m² | Volume: max 3600m³
Spraying Time ≤ 10 seconds
Power Source DC24V / 1.6A
Max Working Pressure 5.6Mpa 8.0Mpa
Available Capacities (L) 16 / 32 / 40 / 70 / 90 / 120 / 150 / 250 / 350 / 500 L
Cylinder Spec 1
Cylinder Spec 2
Product Application Scenarios

The FK5112 Total Flooding System is ideal for environments where water-based suppression could damage sensitive equipment. Key applications include:

  • Data Centers & Server Rooms: Protects critical IT hardware without water damage.
  • Telecommunication Facilities: Safe for switching equipment and clean rooms.
  • Museums & Archives: Preserves irreplaceable artifacts and documents.
  • Medical Facilities: Guards high-value diagnostic and life-support equipment.
  • Industrial Control Rooms: Ensures continuity in energy and manufacturing plants.
Application Overview
Production & Packaging
Factory Production
Quality Control
Packaging 1
Packaging 2
Shipping
Frequently Asked Questions
What is the FK-5112 (Novec 1230) extinguishing agent?
FK-5112 is a clean agent fire suppressant that is non-conductive, leaves no residue, and is safe for high-value electronic equipment and sensitive environments.
How fast does the system react to a fire?
The system is designed for rapid discharge, typically releasing the agent within 10 seconds of activation to suppress the fire in its earliest stages.
Is this fire suppression system safe for occupied spaces?
Yes, the agents used (FK-5112/FM200) are non-toxic at designed concentrations and are safe for human exposure during discharge in protected areas.
Can the system be customized for my specific room size?
Absolutely. We provide one-to-one customization, calculating the required cylinder capacity and piping layout based on the exact dimensions and height of your facility.
What certifications does the system hold?
Our fire suppression systems are CCC (China Compulsory Certification) certified and manufactured under ISO9001 quality management standards.
Does the agent damage computers or servers?
No. Since it is a clean, non-conductive gas, it penetrates around equipment without causing short circuits or leaving messy residue, making it ideal for data centers.

Related Products